High-voltage interlock circuit fault
What it means
The safety loop that confirms all high-voltage connectors and covers are closed has been interrupted, so the system blocks high voltage.
Symptoms
- Hybrid/EV warning light
- Car will not go into READY or drive mode
Likely causes, most likely first
| No. | Cause |
|---|---|
| 01 | service plug / disconnect not fully seated |
| 02 | high-voltage connector or inverter cover not fully fitted after work |
| 03 | corroded or damaged interlock wiring |
| 04 | faulty interlock switch in a high-voltage component |
What to check, step by step
- 01Ask whether any high-voltage work was done recently
- 02Have a high-voltage qualified technician check the service plug and all high-voltage connector locks and covers
- 03Check interlock wiring continuity
- 04Clear codes and re-test